H 7100

Advanced Hematology Analyzer
Meet the H 7100
The H 7100 is an advanced hematology analyzer offering comprehensive CBC, differential, and reticulocyte analysis. Designed to redefine hematology testing, this state-of-the-art diagnostic system delivers accurate and reliable blood analysis for the evolving needs of clinical laboratories and research facilities.

Product Specifications

1
Parameters
70+ Parameters
Your Benefit:

Comprehensive parameter coverage enables precise diagnosis of anemia, leukemia, infection, and inflammation, reducing the need for additional smear reviews.

f2
Diffrentiator of IDA & Beta Thalassemia
Reports Mentzer Index and RDWI
Your Benefit:

Enables reliable differentiation between Iron Deficiency Anaemia (IDA) and Beta Thalassemia with high sensitivity and specificity in microcytic hypochromic anemia cases.

f3
Reporting
Reporting of NLR, PLR, LMR & NRBC
Your Benefit:
  • NLR is a novel prognostic marker for cancer, sepsis, cardiovascular disease (CVD), and post-operative complications.
  • NRBC reporting helps identify conditions such as hemolytic anaemia, leukemoid reaction, sepsis, and thalassemia.

f4
Advanced References
Retics Panel, IPF & Immature Granulocyte (IG)
Your Benefit:
  • IPF enables early detection of bone marrow recovery, making it valuable for chemotherapy and stem cell transplant patients.
  • IG count aids risk stratification in sepsis and critical illness.
f5
Cutting-Edge Technology
Fluorescence Flow Cytometry + Laser Scattering
Your Benefit:

Combines laser scattering, fluorescence technology, and flow cytometry for detailed WBC subtype differentiation and accurate reticulocyte quantification, improving diagnostic precision.

f7
Efficient Handling
Autoloader with 60-Tube Continuous Loading Capacity
Your Benefit:

Streamlines workflow through auto-mixing, reducing manual handling errors and enabling efficient processing of large sample volumes with minimal user intervention.

f6
Storage
1,50,000 Results with Graphs on Analyser; 5,00,000 on PC
Your Benefit:

Large data storage enables easy access to historical patient results for monitoring clinical progress over time.

ChatGPT Image Jun 18, 2026, 11_48_01 PM
Effortless Interaction
12.1" TFT Touch Screen Display
Your Benefit:

Intuitive navigation and a user-friendly interface simplify operation, data input, and result interpretation, enhancing overall laboratory efficiency.

Fully Automated 6-part differential Hematology Analyzer for clinical laboratories and research facilities requiring comprehensive CBC, differential, and reticulocyte analysis.
Technical Specification

Mode Type

Whole Blood, Predilute, Capillary

Autoloader

60 Tubes; Continuous Loading with Auto-Mixing

Reportable Parameters

42 Reportable Parameters

Research Parameters

29 Research Parameters

Body Fluid Parameters

7 Reportable Parameters and 11 Research Parameters

Principle of Measurement

RBC / PLT / WBC: Electrical Impedance & Optical Detection

WBC Differential

Fluorescence Flow Cytometry

Reticulocyte Analysis

Fluorescence Flow Cytometry

Haemoglobin Measurement

Cyanide-Free Colorimetry

MCV / HCT

MCV: Measured | HCT: Calculated

Histograms

3 (RBC / WBC / PLT)

Scattergrams

8 (2D Scattergrams), 2 (3D Scattergrams)

QR Code Reader

Reads Sample Barcodes and Enables Direct QC Value Entry

Sample Volume

Whole Blood: 35 µL | Pre-diluted: 20 µL | Capillary: 20 µL

Linearity Range – WBC

0–500 × 10³/µL

Linearity Range – RBC

0–8.6 × 10⁶/µL

Linearity Range – HGB

0–26.0 g/dL

Linearity Range – HCT

0–75%

Linearity Range – PLT

0–5000 × 10³/µL

Calibrator

ELite H Cal

Tri-Level Controls

Erba H7 CON L, N, H | Erba H7 Ret CON L, N, H

Open Vial Stability

14 Days at 2–8°C

Throughput

Up to 100 Tests/Hour

Quality Control

500 Files with Levey-Jennings Graphs and X-Bar Analysis

Data Storage

Analyzer: 1,50,000 Results with Graphs | PC: 5,00,000 Results

Dimensions (mm)

665 × 870 × 820 (W × H × D)

Weight (kg)

≤ 100

Interfaces

4 USB Ports + 1 LAN Port (HL7, TCP/IP; LIS Connectivity) — Bi-directional Communication

Touch Screen

12.1" TFT Touch Screen

Operating Temperature

15–40°C

Humidity

30–90%

Power Requirement

AC 100–240 V with Built-in Voltage Stabiliser, 50/60 Hz, 200 VA

System General

System Type

Discrete, automated, random access, patient prioritized, clinical chemistry analyzer, 1,2, 3 reagent system

Throughput

Upto 1040 tests/hr (800 tests/hr) photometric and 240 tests/hr with ISE (4 Channel)*

Analytical Methods

1-Point, 2-Point, Rate-A, Rate-B, Direct Potentiometry

Barcode Reader

For reagents and samples

Reaction Tray

147 hard glass cuvettes

Reaction Mixing

Stirrer with variable speed

Reading Volume

Reaction volume 150 ul

On-board Laundry

7 stage cleaning, 2 stage drying

Photometer

Multi-wavelength diffraction grating with 15 wavelengths (340, 376, 405, 450, 480, 505, 528, 546, 570, 600, 628, 660, 700, 750 and 800 nm)

Calibration

K-Factor, Linear (1, 2 point & multipoint), 4P and SP Logit-log, cubic spline, exponential, polynomial. On-board serial dilution for calibrator

OD Range

0.0 - 3.0

Light Source

Tungsten halogen lamp

Detector

Silicon photo-diode

Water Consumption

<25 litres /hr

Programmable Parameters:

Default system pack parameters + upto 99 user defined parameters, Unlimited profiles and unlimited calculation items

Quality Control

QC plot data with QC rules. Provision for lab mean. Twin plot

Power Requirement

AC220V± 10%,50 Hz or AC 110 V± 10%, 60 Hz

Power Consumption

2000VA.

Dimensions (mm)

Approx . 1350 (L) x 1000 (D) x 1250 (H)

Weight

Approx . 275 kgs.

Sample

Serum, Urine, Plasma, CSF, whole blood, other.

Standard / STAT Carousal

44 positions

Sample Rack

Upto 150 samples can be placed simultaneously (excluding standards, calibrators & controls)

Sample Pipetting

2 -60 µl (adjustable in 0.1 µIstep) for Biochemistry, 70 µl (fixed) for ISE Capacitance probe with level sensing, vertical obstruction detection, Clot detection and serum indices

Auto Rerun

Repeat with same, increased or decreased volume (upto 1:150)

Sample Tubes/ Cups

Primary tubes of 5 ml, 7 ml, 10 ml and sample cups

Reagent Tray

86 reagent positions with on-board refrigeration

Reagent Pipetting

Two separate probes for Rl, R2 & R3 Rl:60-300 µl (adjustable in 0.5 µl)

R2

0, or 10- 200 µl (adjustable in 0.5 µl)

R3

0, or 10- 200 µl (adjustable in 0.5 µl) Capacitance probe with liquid level sensing & vertical obstruction detection

Analyzer - PC

RS - 232 C Serial Port PC - Host

Computer

Bidirectional TCP/IP & RS-232

PC - Printer

USB

Operating system

Windows-based

Database

Unlimited results

How many parameters does the H 7100 have?
The H 7100 offers 70+ parameters, including 42 reportable parameters, 29 research parameters, and Body Fluid mode parameters.
The H 7100 stores 1,50,000 results with graphs on the analyzer and up to 5,00,000 results on the PC.
The H 7100 uses two lyse reagents—H 7100 Lyse 1 and H 7100 Lyse 2. In total, the system uses seven reagents.
Yes. The H 7100 features a 60-tube autoloader with continuous loading and auto-mixing.
The H 7100 uses Fluorescence Flow Cytometry for WBC differential analysis and reticulocyte quantification.
The H 7100 offers a throughput of up to 100 tests per hour.
Yes. The H 7100 supports bi-directional LIS connectivity via HL7 and TCP/IP protocols.
Whole Blood: 35 µL | Pre-diluted: 20 µL | Capillary: 20 µL

Reagent Information

H clean (4 ml)
An alkaline cleaning solution used to soak and clean tubes and chambers..
H 7100 Lyse 1
Breaks down RBC & PLT, release HGB and react with HGB to generate a mixture,..
H 7100 Lyse 2
Chemical staining for WBC and white blood cell classification..
H 7100 Dil
Diluent is used to dilute blood sample for combuting blood cells, Provide an environment (similar..
H 7100 Dil Ret
Diluent is used to dilute blood sample for computing reticulocytes , Provide an environment (similar..
H7100 Fluro Ret
Dye to stain reticulocytes..
H7100 Fluro Diff
Dye to compute differentials..
No data found
No data found

Hear it From Our Happy Customers

Expert Speak

Resources

That’s all for now
That’s all for now

News

19 Apr 2024

Add Your Heading Text Here ErbaLisa HCV Gen 4 Ag+Ab | India’s first and only...

News

15 May 2024

Timely and targeted diagnosis is key for the development of disease prevention programs and optimal...

News

15 May 2024

Dr. Ravi Kannan of Cachar Cancer Hospital Awarded Padma Shri Dr Ravi Kannan, a renowned...

People Also Look For

WhatsApp

Enquiry form

Product Name

H 7100

Product Category

Enquiry form