XL 180

Fully Automatic Clinical Chemistry Analyser
Meet the XL 180

The Erba XL 180 is a fully automated clinical chemistry analyser designed for small to medium-sized laboratories. It offers convenience and flexibility in operation, combining rugged architecture and a precise optical system to deliver good quality reports.

Its simple, easy-to-use software guides the system through every step of the assay procedure, optimises sample processing and presents data graphically.

Product Specifications

Throughput
180 photometric tests/hour and 360 tests/hour with the optional ISE module.
Your Benefit:

Lorem ipsum dolor sit amet, consectetur adipiscing elit.

Sample and Reagent Positions
25 fixed reagent positions and 15 flexible sample/reagent positions, with 10 fixed sample positions. Onboard cooling for reagents.
Your Benefit:

Lorem ipsum dolor sit amet, consectetur adipiscing elit.

Easy-to-Use Software
Simple, easy-to-use software guides the assay procedure, optimises sample processing and presents data graphically.
Your Benefit:

Lorem ipsum dolor sit amet, consectetur adipiscing elit.

Auto Dilution and Auto Rerun
Auto dilution and auto rerun facility, with flexibility for STAT samples.
Your Benefit:

Lorem ipsum dolor sit amet, consectetur adipiscing elit.

Probe Safety Features
Probe with pre-heating facility, vertical obstruction detection and liquid level sensing.
Your Benefit:

Lorem ipsum dolor sit amet, consectetur adipiscing elit.

Barcode Reader
Inbuilt barcode reader for samples and reagents.
Your Benefit:

Lorem ipsum dolor sit amet, consectetur adipiscing elit.

Routine Chemistry
Special Chemistry
Immunoturbidimetric Tests
Electrolyte Testing: Sodium (Na), Potassium (K), Chloride (Cl) and Lithium (Li), with optional ISE module.
System General

System Type

Discrete, automated, random access, patient prioritized, clinical chemistry analyzer, 1,2, 3 reagent system

Throughput

Upto 1040 tests/hr (800 tests/hr) photometric and 240 tests/hr with ISE (4 Channel)*

Analytical Methods

1-Point, 2-Point, Rate-A, Rate-B, Direct Potentiometry

Barcode Reader

For reagents and samples

Reaction Tray

147 hard glass cuvettes

Reaction Mixing

Stirrer with variable speed

Reading Volume

Reaction volume 150 ul

On-board Laundry

7 stage cleaning, 2 stage drying

Photometer

Multi-wavelength diffraction grating with 15 wavelengths (340, 376, 405, 450, 480, 505, 528, 546, 570, 600, 628, 660, 700, 750 and 800 nm)

Calibration

K-Factor, Linear (1, 2 point & multipoint), 4P and SP Logit-log, cubic spline, exponential, polynomial. On-board serial dilution for calibrator

OD Range

0.0 - 3.0

Light Source

Tungsten halogen lamp

Detector

Silicon photo-diode

Water Consumption

<25 litres /hr

Programmable Parameters:

Default system pack parameters + upto 99 user defined parameters, Unlimited profiles and unlimited calculation items

Quality Control

QC plot data with QC rules. Provision for lab mean. Twin plot

Power Requirement

AC220V± 10%,50 Hz or AC 110 V± 10%, 60 Hz

Power Consumption

2000VA.

Dimensions (mm)

Approx . 1350 (L) x 1000 (D) x 1250 (H)

Weight

Approx . 275 kgs.

Sample

Serum, Urine, Plasma, CSF, whole blood, other.

Standard / STAT Carousal

44 positions

Sample Rack

Upto 150 samples can be placed simultaneously (excluding standards, calibrators & controls)

Sample Pipetting

2 -60 µl (adjustable in 0.1 µIstep) for Biochemistry, 70 µl (fixed) for ISE Capacitance probe with level sensing, vertical obstruction detection, Clot detection and serum indices

Auto Rerun

Repeat with same, increased or decreased volume (upto 1:150)

Sample Tubes/ Cups

Primary tubes of 5 ml, 7 ml, 10 ml and sample cups

Reagent Tray

86 reagent positions with on-board refrigeration

Reagent Pipetting

Two separate probes for Rl, R2 & R3 Rl:60-300 µl (adjustable in 0.5 µl)

R2

0, or 10- 200 µl (adjustable in 0.5 µl)

R3

0, or 10- 200 µl (adjustable in 0.5 µl) Capacitance probe with liquid level sensing & vertical obstruction detection

Analyzer - PC

RS - 232 C Serial Port PC - Host

Computer

Bidirectional TCP/IP & RS-232

PC - Printer

USB

Operating system

Windows-based

Database

Unlimited results

What is the throughput of XL 1000 with ISE?
800 tests/hr Photometric & 240 tests/hr ISE- 1040 tests/hr with ISE
150 samples can be placed simultaneously
86 reagent position
86 reagent position are there in XL 1000.
One sample probe , and 2 reagent probes
Mixer 1 split into Stirrer 1A and Stirrer 1B units and Mixer 2 for Reagent 2 & Reagent 3 mixing
44 Stat position are there in XL 1000.

Reagent Information

No data found
No data found
No data found

Hear it From Our Happy Customers

Expert Speak

Resources

That’s all for now
That’s all for now
News
15 May 2024

Timely and targeted diagnosis is key for the development of disease prevention programs and optimal...

News
15 May 2024

Dr. Ravi Kannan of Cachar Cancer Hospital Awarded Padma Shri Dr Ravi Kannan, a renowned...

News
17 May 2024

Biospectrum, December 2021: Launched India’s first high sensitivity Hep C kit Transasia further strengthened its...

People Also Look For

WhatsApp
Enquiry form

Product Name

XL 180

Product Category

Enquiry form