Elan 30s
Fully Automated micro strip ELISA processor.
![](https://erba.velocitabrandconsultants.com/wp-content/uploads/2024/05/1Elan-30s.jpg)
![](https://erba.velocitabrandconsultants.com/wp-content/uploads/2024/05/2Elan-30s.jpg)
![](https://erba.velocitabrandconsultants.com/wp-content/uploads/2024/05/3Elan-30s.jpg)
![](https://erba.velocitabrandconsultants.com/wp-content/uploads/2024/05/4Elan-30s.jpg)
Elan 30s
Fully Automated micro strip ELISA processor.
Meet the Elan 30s
Product Specifications
![f1 f1](https://erba.velocitabrandconsultants.com/wp-content/uploads/elementor/thumbs/f1-8-qofyv2dv2990a3770wwheceng2c0pgvaa3ntr3i0lc.png)
Intended Use
Compact benchtop model
Your Benefit:
Ideal for users seeking automation even with lesser space & moderate workload
![f2 f2](https://erba.velocitabrandconsultants.com/wp-content/uploads/elementor/thumbs/f2-8-qofyv3bp93aalp5tvfb3yu641g7dx5z0m8bb8dgmf4.png)
Modules
All modules in 1 unit
Your Benefit:
Pipetting module, Incubator, Shaker Washer, Reader all modules in same unit allow complete automation from Sample
![f3 f3](https://erba.velocitabrandconsultants.com/wp-content/uploads/elementor/thumbs/f3-8-qofyv3bp93aalp5tvfb3yu641g7dx5z0m8bb8dgmf4.png)
Flexibility
6 parameters in a batch
Your Benefit:
Allows multiple parameters to be run in a single batch
![f4 f4](https://erba.velocitabrandconsultants.com/wp-content/uploads/elementor/thumbs/f4-8-qofyv3bp93aalp5tvfb3yu641g7dx5z0m8bb8dgmf4.png)
Dispensing System
Flexible pipetting module
Your Benefit:
Allows user flexibility to use disposable tips or probe for dispensing of samples depending on the parameter
![f5 f5](https://erba.velocitabrandconsultants.com/wp-content/uploads/elementor/thumbs/f5-8-qofyv49jfxbkxb4gpxpqjbxkmu2r4v2qycyspnf88w.png)
Sample Positions
59 Sample locations
Your Benefit:
Allows to process maximum load in single batch
![f6 f6](https://erba.velocitabrandconsultants.com/wp-content/uploads/elementor/thumbs/f6-5-qofyv49jfxbkxb4gpxpqjbxkmu2r4v2qycyspnf88w.png)
Samples & Reagrents flexibility
Interchangeable Sample positions
Your Benefit:
Allows use of sample positions for reagents to overcome issues related to dead volume
![f7 f7](https://erba.velocitabrandconsultants.com/wp-content/uploads/elementor/thumbs/f7-4-qofyv49jfxbkxb4gpxpqjbxkmu2r4v2qycyspnf88w.png)
Reagent position
24 reagent locations & option for common reagent position
Your Benefit:
Same reagent can be used for multiple assays helps to retain the stability of reagents for longer time
![f8 f8](https://erba.velocitabrandconsultants.com/wp-content/uploads/elementor/thumbs/f8-qofyv57dmrcv8x33kg4d3tp187y4ck6hahma6xdu2o.png)
Security
Security at each level
Your Benefit:
Ensures Liquid level sensing, clot detection and tip Detection
ELISA
Technical specification
Dimensions
- Length: 1058mm 3.5ft
- Breadth: 520mm 1.8ft
- Height: 533mm 1.8ft
- Weight: 65kgs
- Shipping weight: 95kgs
Power Supply
- Voltage: AC 110 – 240 V
- Frequency: 50 Hz / 60 Hz
- Power consumption: 300 W
Reader Specifications
- Dynamic range: 0.0 - 4.0 O.D
- Wavelength range: 400 - 800 nm
- Filter slots: 405 nm, 450 nm, 492 nm & 630 nm (3 open positions)
- Reading mode: Single & Dual
- Reading time: 20 sec per strip for single wavelength
- Precision: At 405nm and 450nm :
< 2% CV at 0.5 to 2.0 OD - Accuracy: ± 3%OD at 0.25 OD to 2.5 OD
Washer Specifications
- Manifold configuration: 8 for aspiration & 8 for dispensing
- Wash cycle: 1 to 9 (repeatable)
- Residual volume: < 5 μl
- Washer buffer capacity: 3 × 1L
- Low buffer alarm
- Soak time: 20 to 60 sec
- Dispense pressure: Pre-set
- Rinse function
- Waste bottle: 1 × 2L
Pipetting Specifications
- Dispensing mode: Fixed needle or Disposable tips
- Sample tips range: 300 μl (5-200 μl)
- Reagent tip range: 300 μl (10-200 μl)
- Precision sample tip: < 2% CV at 10 μl
< 1% CV at 100 μl - Precision reagent tip: +/- 2 % of the Target Volume above 50 μl
Process Security
- Liquid level sensing
- Level sensor system: Conductive
- Clot detection
- Tip detection
- Alarms
Software
- Computer include: Desktop PC running TBM O.S (Windows based
- Controlling software: ELAN 30s
- Work protocols (assay): Unlimited
- Data Processing: Quantitative & Qualitative
- Levey-Jennings
- West guard rules
- Process reporting: Event log + error log
- Automatic error recovery
- Password access control
Consumables
- Probe clean solution: XL Wash
- Carbonated disposable tips: Sample tips (optional)
- Reagent tips (optional)
System General
System Type
Discrete, automated, random access, patient prioritized, clinical chemistry analyzer, 1,2, 3 reagent system
Throughput
Upto 1040 tests/hr (800 tests/hr) photometric and 240 tests/hr with ISE (4 Channel)*
Analytical Methods
1-Point, 2-Point, Rate-A, Rate-B, Direct Potentiometry
Barcode Reader
For reagents and samples
Reaction Tray
147 hard glass cuvettes
Reaction Mixing
Stirrer with variable speed
Reading Volume
Reaction volume 150 ul
On-board Laundry
7 stage cleaning, 2 stage drying
Photometer
Multi-wavelength diffraction grating with 15 wavelengths (340, 376, 405, 450, 480, 505, 528, 546, 570, 600, 628, 660, 700, 750 and 800 nm)
Calibration
K-Factor, Linear (1, 2 point & multipoint), 4P and SP Logit-log, cubic spline, exponential, polynomial. On-board serial dilution for calibrator
OD Range
0.0 - 3.0
Light Source
Tungsten halogen lamp
Detector
Silicon photo-diode
Water Consumption
<25 litres /hr
Programmable Parameters:
Default system pack parameters + upto 99 user defined parameters, Unlimited profiles and unlimited calculation items
Quality Control
QC plot data with QC rules. Provision for lab mean. Twin plot
Power Requirement
AC220V± 10%,50 Hz or AC 110 V± 10%, 60 Hz
Power Consumption
2000VA.
Dimensions (mm)
Approx . 1350 (L) x 1000 (D) x 1250 (H)
Weight
Approx . 275 kgs.
Sample Handling
Sample
Serum, Urine, Plasma, CSF, whole blood, other.
Standard / STAT Carousal
44 positions
Sample Rack
Upto 150 samples can be placed simultaneously (excluding standards, calibrators & controls)
Sample Pipetting
2 -60 µl (adjustable in 0.1 µIstep) for Biochemistry, 70 µl (fixed) for ISE Capacitance probe with level sensing, vertical obstruction detection, Clot detection and serum indices
Auto Rerun
Repeat with same, increased or decreased volume (upto 1:150)
Sample Tubes/ Cups
Primary tubes of 5 ml, 7 ml, 10 ml and sample cups
Reagent Handling
Reagent Tray
86 reagent positions with on-board refrigeration
Reagent Pipetting
Two separate probes for Rl, R2 & R3 Rl:60-300 µl (adjustable in 0.5 µl)
R2
0, or 10- 200 µl (adjustable in 0.5 µl)
R3
0, or 10- 200 µl (adjustable in 0.5 µl) Capacitance probe with liquid level sensing & vertical obstruction detection
System Interface
Analyzer - PC
RS - 232 C Serial Port PC - Host
Computer
Bidirectional TCP/IP & RS-232
PC - Printer
USB
Operating system
Windows-based
Database
Unlimited results