ECL 105
Single channel semi automated coagulation analyzer
ECL 105
Single channel semi automated coagulation analyzer
Meet the ECL 105
Product Specifications
Detection
Optical Detection at 640 nm
Your Benefit:
Helps to overcome HIL interference
Clotting & Immunotrubidometry Assays
Clotting and Immunoturbidometry assays for Routine & Special parameters
Your Benefit:
Multi-Parameter testing helps Clinicians to diagnose better
Display
Touchscreen for data entry
Your Benefit:
Ensures ease of operation
Results
Automated results calculation
Your Benefit:
Supports in ease of clinical interpretations
Quality Control
Quality Control with L-J chart
Your Benefit:
Ensures test results are as per guidelines
Compatibility
LIS Compatibility
Your Benefit:
Ensures the elimination of transcription errors
PT
APTT
TT
Fibrinogen
Coag. Factors
D-Dimer
Protein S
Lupus Anticoagulans
Technical Specification
Universal power supply
100-250V~47-63Hz
Dimensions
216 x 205 x 75 mm
Weight
1 kg
2 USB ports (1 x type A, 1 x type B)
System General
System Type
Discrete, automated, random access, patient prioritized, clinical chemistry analyzer, 1,2, 3 reagent system
Throughput
Upto 1040 tests/hr (800 tests/hr) photometric and 240 tests/hr with ISE (4 Channel)*
Analytical Methods
1-Point, 2-Point, Rate-A, Rate-B, Direct Potentiometry
Barcode Reader
For reagents and samples
Reaction Tray
147 hard glass cuvettes
Reaction Mixing
Stirrer with variable speed
Reading Volume
Reaction volume 150 ul
On-board Laundry
7 stage cleaning, 2 stage drying
Photometer
Multi-wavelength diffraction grating with 15 wavelengths (340, 376, 405, 450, 480, 505, 528, 546, 570, 600, 628, 660, 700, 750 and 800 nm)
Calibration
K-Factor, Linear (1, 2 point & multipoint), 4P and SP Logit-log, cubic spline, exponential, polynomial. On-board serial dilution for calibrator
OD Range
0.0 - 3.0
Light Source
Tungsten halogen lamp
Detector
Silicon photo-diode
Water Consumption
<25 litres /hr
Programmable Parameters:
Default system pack parameters + upto 99 user defined parameters, Unlimited profiles and unlimited calculation items
Quality Control
QC plot data with QC rules. Provision for lab mean. Twin plot
Power Requirement
AC220V± 10%,50 Hz or AC 110 V± 10%, 60 Hz
Power Consumption
2000VA.
Dimensions (mm)
Approx . 1350 (L) x 1000 (D) x 1250 (H)
Weight
Approx . 275 kgs.
Sample Handling
Sample
Serum, Urine, Plasma, CSF, whole blood, other.
Standard / STAT Carousal
44 positions
Sample Rack
Upto 150 samples can be placed simultaneously (excluding standards, calibrators & controls)
Sample Pipetting
2 -60 µl (adjustable in 0.1 µIstep) for Biochemistry, 70 µl (fixed) for ISE Capacitance probe with level sensing, vertical obstruction detection, Clot detection and serum indices
Auto Rerun
Repeat with same, increased or decreased volume (upto 1:150)
Sample Tubes/ Cups
Primary tubes of 5 ml, 7 ml, 10 ml and sample cups
Reagent Handling
Reagent Tray
86 reagent positions with on-board refrigeration
Reagent Pipetting
Two separate probes for Rl, R2 & R3 Rl:60-300 µl (adjustable in 0.5 µl)
R2
0, or 10- 200 µl (adjustable in 0.5 µl)
R3
0, or 10- 200 µl (adjustable in 0.5 µl) Capacitance probe with liquid level sensing & vertical obstruction detection
System Interface
Analyzer - PC
RS - 232 C Serial Port PC - Host
Computer
Bidirectional TCP/IP & RS-232
PC - Printer
USB
Operating system
Windows-based
Database
Unlimited results