Medica Corporation’s EasyLyte® analyzer is a completely automated
Meet the EasyLyte
Medica Corporation’s EasyLyte® analyzer is a completely automated, microprocessor-controlled electrolyte system that uses ISE (Ion Selective Electrode) technology to make electrolyte measurements. The EasyLyte measures combinations of Na+, K+, in whole blood, serum, plasma, or urine.EasyLyte incorporates state-of-the-art electronics and an innovative ergonomic design that differentiates it significantly from competitors. The analyzer also stores quality-control data that is easily accessible. Patient histories are immediately retrievable for evaluation.EasyLyte analyzers combine simple yes/no prompted operation, low maintenance, and high reliability into one economical design.

DOWNLOAD BROCHURE

Product Specifications

Lorem ipsum
EasyLyte is Easy to Use, Easy to Operate, Easy to Maintain
Your Benefit:

Lorem ipsum dolor sit amet, consectetur adipiscing elit.

Lorem ipsum
The entire menu is driven by 2 simple buttons
Your Benefit:

Lorem ipsum dolor sit amet, consectetur adipiscing elit.

Lorem ipsum
Results are displayed on LCD screen as well as printouts
Your Benefit:

Lorem ipsum dolor sit amet, consectetur adipiscing elit.

Lorem ipsum
EasyLyte does 2 point as well as 1 point calibration
Your Benefit:

Lorem ipsum dolor sit amet, consectetur adipiscing elit.

Lorem ipsum
Facility to analyze different type of samples: whole blood, serum, plasma ,urine samples EasyLyte has capillary and syringe sampling facility
Your Benefit:

Lorem ipsum dolor sit amet, consectetur adipiscing elit.

Lorem ipsum
EasyLyte has auto probe wiping facility
Your Benefit:

Lorem ipsum dolor sit amet, consectetur adipiscing elit.

Lorem ipsum
Analysis of electrolytes is done using 100ul of blood and 400ul of diluted urine
Your Benefit:

Lorem ipsum dolor sit amet, consectetur adipiscing elit.

Lorem ipsum
Rate of analysis 55 secs per sample
Your Benefit:

Lorem ipsum dolor sit amet, consectetur adipiscing elit.

Lorem ipsum
Analyzer is capable of storing 128 patients data with trilevel QC results
Your Benefit:

Lorem ipsum dolor sit amet, consectetur adipiscing elit.

Lorem ipsum
Analyzer has modular plug in reagent pack system
Your Benefit:

Lorem ipsum dolor sit amet, consectetur adipiscing elit.

Lorem ipsum
Analyzer has facility to upgrade to a walk away Electrolyte station by use of Auto Sampler
Your Benefit:

Lorem ipsum dolor sit amet, consectetur adipiscing elit.

Lorem ipsum
EasyLyte has facility for auto calibrations with a programmed interval of 4 hrs and also calibration on demand
Your Benefit:

Lorem ipsum dolor sit amet, consectetur adipiscing elit.

Lorem ipsum
It has a built in thermal printer and a RS 232 port for interfacing
Your Benefit:

Lorem ipsum dolor sit amet, consectetur adipiscing elit.

Sodium - Na, Potassium - K
System General

CLIA Classification

Moderate Complexity

Sample Type

Whole Blood, Serum, Plasma or Urine

Sample Size

100 µL Whole Blood, Serum, Plasma, 60 µL capillary or 400 µL diluted (1:10) Urine

Method

Direct measurement by Ion Selective Electrode (ISE)

Data Storage:

  • Patient Results: up to 128 samples
  • QC Results: up to 20 each Normal, Low, and High

Output

  • 128 x 64 pixel graphic display
  • 24 column thermal printer
  • Serial port (RS-232), EasySampler port

Calibration

Automatic or On-Demand

Ambient Conditions

15–32oC (60–90oF), <85% humidity

Power

100-240 VAC 50/60 Hz, 0.8A

Size & Weight

9.5”W x 16.5”H x 8.0”D (24 cm W x 42 cm H x 20 cm D) 13 lbs. (5.8 kg)

System General

System Type

Discrete, automated, random access, patient prioritized, clinical chemistry analyzer, 1,2, 3 reagent system

Throughput

Upto 1040 tests/hr (800 tests/hr) photometric and 240 tests/hr with ISE (4 Channel)*

Analytical Methods

1-Point, 2-Point, Rate-A, Rate-B, Direct Potentiometry

Barcode Reader

For reagents and samples

Reaction Tray

147 hard glass cuvettes

Reaction Mixing

Stirrer with variable speed

Reading Volume

Reaction volume 150 ul

On-board Laundry

7 stage cleaning, 2 stage drying

Photometer

Multi-wavelength diffraction grating with 15 wavelengths (340, 376, 405, 450, 480, 505, 528, 546, 570, 600, 628, 660, 700, 750 and 800 nm)

Calibration

K-Factor, Linear (1, 2 point & multipoint), 4P and SP Logit-log, cubic spline, exponential, polynomial. On-board serial dilution for calibrator

OD Range

0.0 - 3.0

Light Source

Tungsten halogen lamp

Detector

Silicon photo-diode

Water Consumption

<25 litres /hr

Programmable Parameters:

Default system pack parameters + upto 99 user defined parameters, Unlimited profiles and unlimited calculation items

Quality Control

QC plot data with QC rules. Provision for lab mean. Twin plot

Power Requirement

AC220V± 10%,50 Hz or AC 110 V± 10%, 60 Hz

Power Consumption

2000VA.

Dimensions (mm)

Approx . 1350 (L) x 1000 (D) x 1250 (H)

Weight

Approx . 275 kgs.

Sample

Serum, Urine, Plasma, CSF, whole blood, other.

Standard / STAT Carousal

44 positions

Sample Rack

Upto 150 samples can be placed simultaneously (excluding standards, calibrators & controls)

Sample Pipetting

2 -60 µl (adjustable in 0.1 µIstep) for Biochemistry, 70 µl (fixed) for ISE Capacitance probe with level sensing, vertical obstruction detection, Clot detection and serum indices

Auto Rerun

Repeat with same, increased or decreased volume (upto 1:150)

Sample Tubes/ Cups

Primary tubes of 5 ml, 7 ml, 10 ml and sample cups

Reagent Tray

86 reagent positions with on-board refrigeration

Reagent Pipetting

Two separate probes for Rl, R2 & R3 Rl:60-300 µl (adjustable in 0.5 µl)

R2

0, or 10- 200 µl (adjustable in 0.5 µl)

R3

0, or 10- 200 µl (adjustable in 0.5 µl) Capacitance probe with liquid level sensing & vertical obstruction detection

Analyzer - PC

RS - 232 C Serial Port PC - Host

Computer

Bidirectional TCP/IP & RS-232

PC - Printer

USB

Operating system

Windows-based

Database

Unlimited results

What is the throughput of XL 1000?
800 Tests/Hour Photometric & 1040 tests/hour with ISE
Permanent Hard Glass Cuvettes. Glass cuvettes provide excellent optical clarity, allowing accurate and precise measurement, their reusability and durability make them cost effective over time, reducing the need of frequent replacement.
Grating Photometer provides accurate measurements, improved sensitivity and more test options due to 15 adjustable wavelengths.
86 reagent and 150 sample positions with additional 44 position tray for STAT, Controls & Calibrators are available in XL 1000
In XL 1000 44 Position separate carousel is available for STAT position
XL 1000 has water consumption of 25 ltrs/hour
XL 1000 is a floor type fully automated clinical chemistry analyzer.
Trilateral probe system. 2 reagent & 1 sample probe.
4 mixing probes are available in XL 1000
Vertical obstruction detection, Capacitance based liquid level sensing, Clot Detection & Froth detection.
XL 1000 has 10 step Twin laundry system.
Reflex testing reduces the need for manual intervention and decision making by laboratory staff, streamlining testing processes and reducing turnaround times for critical results, which is especially beneficial in emergency or time sensitive situations.
Yes, Automated detection and reporting of serum indices streamline laboratory workflows by minimizing the need for manual inspection and assessment of sample quality, reducing turnaround times and increasing overall laboratory efficiency..
A wide range of equipment and reagents for product segments ranging from semi-automatic clinical chemistry analyzer, fully automated clinical chemistry analyzer, three-part hematology analyzer, five part hematology analyzer, High end five part hematology analyzer, CLIA, ELISA Reader & Washer, Critical care, Urine analysis, Hemostasis and HPLC are available at TBM.

Reagent Information

No data found
No data found
No data found

Hear it From Our Happy Customers

Expert Speak

Resources

Blog

26 Jun 2024

A blood test today holds the key to every treatment outcome. In the wake of...

Blog

26 Jun 2024

The automation of ELISA systems, in the recent past, has contributed to improving the turnaround...

Blog

26 Jun 2024

Diabetes affects approximately 1 in 10 adults globally, with over 90% of cases being attributed...

Whitepaper

19 Apr 2024

Abstract Introduction: Fresh Frozen Plasma (FFP) is a blood component separated from whole blood and...

Whitepaper

25 Jun 2024

Click to know more: http://www.mdpub.net/?mno=132810 Introduction: Dengue is a highly prevalent mosquito-borne disease caused by...

Whitepaper

25 Jun 2024

Introduction: Electrolytes in the body are electrically charged minerals—such as sodium, potassium, calcium, phosphorous, and...

News

19 Apr 2024

Add Your Heading Text Here ErbaLisa HCV Gen 4 Ag+Ab | India’s first and only...

News

15 May 2024

Timely and targeted diagnosis is key for the development of disease prevention programs and optimal...

News

15 May 2024

Dr. Ravi Kannan of Cachar Cancer Hospital Awarded Padma Shri Dr Ravi Kannan, a renowned...

People Also Look For

WhatsApp

Enquiry form

Product Name

EasyLyte

Product Category

Enquiry form