Product Specifications

Parameters
33 Parameters
Your Benefit:
More clinical parameters reported, reduces smear review

Mentzer Index & RDWI Reporting
Reports Mentzer index and RDWI
Your Benefit:
Enables differentiation between Iron deficiency Anaemia and Beta Thalassemia

NLR Reporting
Reporting of NLR
Your Benefit:
NLR a novel prognostic marker for predicting cancer, sepsis, CVD, and post-operative complications

Fast TAT
Auto loader
Your Benefit:
Faster results for improved TAT

Mechanism
ADDM (Auto Dispense Diluting Mechanism)
Your Benefit:
Auto dispenses predefined volume, reducing contamination and manual errors

Storage
Storage: 1,00,000 Results with Histograms
Your Benefit:
More data storage allows an easy access to old patient samples for monitoring the clinical progress

Linearity
Linearity :WBC - 0~300×10³/μL, PLT - 0 - 3000 x 10^9/L
Your Benefit:
Wide linearity in H360 helps to clinically analyze extreme patient demographics with leukemias, thrombocytosis etc.
CBC + Diff Analysis
Technical Specification
Mode Type
60 Tubes; Continuous Loading with Auto-Mixing
Autoloader
60 Tubes; Continuous Loading with Auto-Mixing
33 Parameters:
CBC: WBC, RBC, Hb, HCT, MCV MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PCT, PDW-SD, PDW-CV, P-LCR, P-LCC, DIFF: Neutrophils % & #, Lymphocytes % & #, Monocytes % & #, Eosinophils % & #, Basophils % & # *ALY % & #, *LIC % & #, *NLR, *Mentzer index and *RDWI *Research use only
Principle of Measurement:
RBC/PLT/WBC : Electrical Impedance
WBC DIFF: Tri-angle Laser Flowcytometry
Hb: Cyanide Free Colorimetry
MCV: Measured
HCT: Calculated
Histograms
3 (RBC/WBC/PLT)
Scattergrams
3 (2D Scattergram), 1 (3D Scattergram)
QR Code Reader
For reading sample bar codes & direct input of QC values
Sample Volume
Whole Blood: 20 µL
Pre- diluted: 20 µL
Capillary: 20 µL
CBC Mode : 13 µL
Linearity Range
WBC : 0 - 300 ( x 103/µL)
RBC : 0 - 300 ( x 103/µL)
Hb: 0 - 25.0 (g/dL)
HCT: 0 - 67 (%)
PLT : 0 - 3000 (x 103/µL)
Calibration
ELite H Cal
Tri-level Controls
Erba H5 CON L, N, H
Open Vial Stability at 2 - 8˚C: 16 Days
Throughput
80 Tests/Hr
Quality Control
500 files with L-J Graph
X- Bar Analysis
Data Storage
1,00,000 Results with Graphs
Dimension (mm)
650x550x610
Weight (kgs)
59
Reagents
ELite 580 Dil
ELite H580Lyse1
ELite H580Lyse2
ELite H580Lyse3
Elite H Clean
Interfaces
4 USB ports ( for connecting external devices including external printers) + 1 LAN Port (HL 7, TCP/IP; LIS connectivity)
Operating Environment Temperature
15-40˚C
Humidity
30-90%
Power Requirement
A.C. 100 - 240 V with built-in voltage stabiliser 50/60Hz, 200 VA
System General
System Type
Discrete, automated, random access, patient prioritized, clinical chemistry analyzer, 1,2, 3 reagent system
Throughput
Upto 1040 tests/hr (800 tests/hr) photometric and 240 tests/hr with ISE (4 Channel)*
Analytical Methods
1-Point, 2-Point, Rate-A, Rate-B, Direct Potentiometry
Barcode Reader
For reagents and samples
Reaction Tray
147 hard glass cuvettes
Reaction Mixing
Stirrer with variable speed
Reading Volume
Reaction volume 150 ul
On-board Laundry
7 stage cleaning, 2 stage drying
Photometer
Multi-wavelength diffraction grating with 15 wavelengths (340, 376, 405, 450, 480, 505, 528, 546, 570, 600, 628, 660, 700, 750 and 800 nm)
Calibration
K-Factor, Linear (1, 2 point & multipoint), 4P and SP Logit-log, cubic spline, exponential, polynomial. On-board serial dilution for calibrator
OD Range
0.0 - 3.0
Light Source
Tungsten halogen lamp
Detector
Silicon photo-diode
Water Consumption
<25 litres /hr
Programmable Parameters:
Default system pack parameters + upto 99 user defined parameters, Unlimited profiles and unlimited calculation items
Quality Control
QC plot data with QC rules. Provision for lab mean. Twin plot
Power Requirement
AC220V± 10%,50 Hz or AC 110 V± 10%, 60 Hz
Power Consumption
2000VA.
Dimensions (mm)
Approx . 1350 (L) x 1000 (D) x 1250 (H)
Weight
Approx . 275 kgs.
Sample Handling
Sample
Serum, Urine, Plasma, CSF, whole blood, other.
Standard / STAT Carousal
44 positions
Sample Rack
Upto 150 samples can be placed simultaneously (excluding standards, calibrators & controls)
Sample Pipetting
2 -60 µl (adjustable in 0.1 µIstep) for Biochemistry, 70 µl (fixed) for ISE Capacitance probe with level sensing, vertical obstruction detection, Clot detection and serum indices
Auto Rerun
Repeat with same, increased or decreased volume (upto 1:150)
Sample Tubes/ Cups
Primary tubes of 5 ml, 7 ml, 10 ml and sample cups
Reagent Handling
Reagent Tray
86 reagent positions with on-board refrigeration
Reagent Pipetting
Two separate probes for Rl, R2 & R3 Rl:60-300 µl (adjustable in 0.5 µl)
R2
0, or 10- 200 µl (adjustable in 0.5 µl)
R3
0, or 10- 200 µl (adjustable in 0.5 µl) Capacitance probe with liquid level sensing & vertical obstruction detection
System Interface
Analyzer - PC
RS - 232 C Serial Port PC - Host
Computer
Bidirectional TCP/IP & RS-232
PC - Printer
USB
Operating system
Windows-based
Database
Unlimited results