H 560

Automated 5 Part Differential Hematology Analyzer
Meet the H 560
Automated 5 Part Differential Analyser

Product Specifications

1
Parameters
36 parameters
Your Benefit:

More clinical parameters reported, reduces smear review

f2
Diffrentiator of IDA & Beta Thalassemia
Reports Mentzer index and RDWI
Your Benefit:

Enables differentiation between Iron deficiency Anaemia and Beta Thalassemia

f3
Reporting
Reporting of NLR & NRBC
Your Benefit:
  • NLR a novel prognostic marker for predicting cancer, sepsis, CVD, and post-operative complications
  • NRBC is helpful to identify hemolytic anaemia, leukemoid reaction, sepsis, thalassemia
f4
Diluting Mechanism
ADDM (Auto Dispense Diluting Mechanism)
Your Benefit:

Auto dispenses predefined volume, reducing contamination and manual errors

f5
Reporting Formats
Customized reporting formats
Your Benefit:

Saves morphological findings & other test results in single report

f6
Storage
Storage: 1,00,000 Results with Histograms
Your Benefit:

More data storage allows an easy access to old patient samples for monitoring the clinical progress

f7
Linearity
Linearity : WBC - 0~300×10³/μL, PLT - 0 - 3000 x 10^9/L
Your Benefit:

Wide linearity in H360 helps to clinically analyze extreme patient demographics with leukemias, thrombocytosis etc.

Complete blood count analyser for mid-size laboratories and those looking to upgrade from 3 part differential system
Technical Specification

Mode Type

Whole blood, Predilute, Capillary

36 Parameters

CBC : WBC, RBC, Hb, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PCT, PDW-CV, PDW-SD, P-LCR, P-LCC.

DIFF : Neutrophils % & #, Lymphocytes % & #, Monocytes % & #, Eosinophils % & #, Basophils % & # *ALY % & #, *LIC % & #, *NRBC % & #, *CWBC, *NLR, RDWI & MENTZER INDEX,*Research use only

Principle of measurement

RBC/PLT: Electrical Impedance
WBC + DIFF: Tri-angle Laser Flowcytometry
Hb: Cyanide-Free Colorimetry
MCV: Measured
HCT: Calculated

Histograms

3 (WBC/RBC/PLT)

Scattergram

3 (2D ), 1 (WBC/Baso)

Throughput

upto 60 Tests/Hr

QR Code Reader

For reading sample bar codes & QC values

Sample Volume

Whole blood : 15 µL
Pre-diluted : 20 µL
Capillary : 20 µL
CBC Mode : 11 µL

Linearity Range

WBC : 0 - 300 ( x 103/µL)
RBC : 0.00 – 8.50 (x 103/µL)
Hb : 0 - 25.0 (g/dL)
HCT : 0 - 67 (%)
PLT : 0 - 3000 (x 103/µL)

Calibrator

ELite H Cal

Tri-level Controls

Elite H5 CON L, N, H

Open Vial Stability at 2-8˚C

16 Days

Data Storage

100,000 Results with Graphs, 100 calibrator results, Reagent log storage for 6 months

Quality Control

500 files with L-J graph
X-Bar Analysis

Dimension (mm)

364x498x431

Weight (Kg)

26.5

Interfaces

4 USB ports (For connecting external devices including external printer) + 1 LAN Port (HL 7, TCP/IP; LIS connectivity)

Operating Environment Temperature

15-40˚C

Humidity

30-90%

Power Requirement

A.C.100-240V with built-in voltage stabiliser
50/60Hz, 200VA

System General

System Type

Discrete, automated, random access, patient prioritized, clinical chemistry analyzer, 1,2, 3 reagent system

Throughput

Upto 1040 tests/hr (800 tests/hr) photometric and 240 tests/hr with ISE (4 Channel)*

Analytical Methods

1-Point, 2-Point, Rate-A, Rate-B, Direct Potentiometry

Barcode Reader

For reagents and samples

Reaction Tray

147 hard glass cuvettes

Reaction Mixing

Stirrer with variable speed

Reading Volume

Reaction volume 150 ul

On-board Laundry

7 stage cleaning, 2 stage drying

Photometer

Multi-wavelength diffraction grating with 15 wavelengths (340, 376, 405, 450, 480, 505, 528, 546, 570, 600, 628, 660, 700, 750 and 800 nm)

Calibration

K-Factor, Linear (1, 2 point & multipoint), 4P and SP Logit-log, cubic spline, exponential, polynomial. On-board serial dilution for calibrator

OD Range

0.0 - 3.0

Light Source

Tungsten halogen lamp

Detector

Silicon photo-diode

Water Consumption

<25 litres /hr

Programmable Parameters:

Default system pack parameters + upto 99 user defined parameters, Unlimited profiles and unlimited calculation items

Quality Control

QC plot data with QC rules. Provision for lab mean. Twin plot

Power Requirement

AC220V± 10%,50 Hz or AC 110 V± 10%, 60 Hz

Power Consumption

2000VA.

Dimensions (mm)

Approx . 1350 (L) x 1000 (D) x 1250 (H)

Weight

Approx . 275 kgs.

Sample

Serum, Urine, Plasma, CSF, whole blood, other.

Standard / STAT Carousal

44 positions

Sample Rack

Upto 150 samples can be placed simultaneously (excluding standards, calibrators & controls)

Sample Pipetting

2 -60 µl (adjustable in 0.1 µIstep) for Biochemistry, 70 µl (fixed) for ISE Capacitance probe with level sensing, vertical obstruction detection, Clot detection and serum indices

Auto Rerun

Repeat with same, increased or decreased volume (upto 1:150)

Sample Tubes/ Cups

Primary tubes of 5 ml, 7 ml, 10 ml and sample cups

Reagent Tray

86 reagent positions with on-board refrigeration

Reagent Pipetting

Two separate probes for Rl, R2 & R3 Rl:60-300 µl (adjustable in 0.5 µl)

R2

0, or 10- 200 µl (adjustable in 0.5 µl)

R3

0, or 10- 200 µl (adjustable in 0.5 µl) Capacitance probe with liquid level sensing & vertical obstruction detection

Analyzer - PC

RS - 232 C Serial Port PC - Host

Computer

Bidirectional TCP/IP & RS-232

PC - Printer

USB

Operating system

Windows-based

Database

Unlimited results

Total how many parameters does H560 have?
H 560 has total 36 parameters in which 26 are reportable and 10 are research parameters.
1 lakh sample data
2 lyse (Lyse 1 and Lyse 2)
H 560 is single tube open cap analysis only.
WBC differential principle is based on Tri angle laser based flow cytometry

Reagent Information

H 560 Diluent
Diluent is used to dilute blood sample, Provide an environment (similar to plasma) to maintain..
H 560 Lyse 1
Breaks down RBC & PLT, release HGB and react with HGB to generate a mixture,..
560 Lyse 1
Breaks down RBC & PLT, release HGB and react with HGB to generate a mixture,..
Erba Elite H clean
An alkaline cleaning solution used to soak and clean tubes and chambers..
560 Lyse 2
Chemical staining for WBC and white blood cell classification..
No data found
No data found

Hear it From Our Happy Customers

Expert Speak

Resources

Blog

26 Jun 2024

A blood test today holds the key to every treatment outcome. In the wake of...

Blog

26 Jun 2024

The automation of ELISA systems, in the recent past, has contributed to improving the turnaround...

Blog

26 Jun 2024

Diabetes affects approximately 1 in 10 adults globally, with over 90% of cases being attributed...

Whitepaper

19 Apr 2024

Abstract Introduction: Fresh Frozen Plasma (FFP) is a blood component separated from whole blood and...

Whitepaper

25 Jun 2024

Click to know more: http://www.mdpub.net/?mno=132810 Introduction: Dengue is a highly prevalent mosquito-borne disease caused by...

Whitepaper

25 Jun 2024

Introduction: Electrolytes in the body are electrically charged minerals—such as sodium, potassium, calcium, phosphorous, and...

News

19 Apr 2024

Add Your Heading Text Here ErbaLisa HCV Gen 4 Ag+Ab | India’s first and only...

News

15 May 2024

Timely and targeted diagnosis is key for the development of disease prevention programs and optimal...

News

15 May 2024

Dr. Ravi Kannan of Cachar Cancer Hospital Awarded Padma Shri Dr Ravi Kannan, a renowned...

People Also Look For

WhatsApp

Enquiry form

Product Name

H 560

Product Category

Enquiry form