ECL 105

Single channel semi automated coagulation analyzer
Meet the ECL 105
It’s a modern and advanced analyzer in Hemostasis. This single channel coagulation analyzer redefines the benefits in its class Erba. ECL 105 can perform PT, APTT, Fibrinogen, Thrombin Time, All Factiors, Lupus and DDimer.

Product Specifications

f1
Detection
Optical Detection at 640 nm
Your Benefit:

Helps to overcome HIL interference

f2
Clotting & Immunotrubidometry Assays
Clotting and Immunoturbidometry assays for Routine & Special parameters
Your Benefit:

Multi-Parameter testing helps Clinicians to diagnose better

f3
Display
Touchscreen for data entry
Your Benefit:

Ensures ease of operation

f4
Results
Automated results calculation
Your Benefit:

Supports in ease of clinical interpretations

f5
Quality Control
Quality Control with L-J chart
Your Benefit:

Ensures test results are as per guidelines

f6
Compatibility
LIS Compatibility
Your Benefit:

Ensures the elimination of transcription errors

PT
APTT
TT
Fibrinogen
Coag. Factors
D-Dimer
Protein S
Lupus Anticoagulans
Technical Specification

Universal power supply

100-250V~47-63Hz

Dimensions

216 x 205 x 75 mm

Weight

1 kg

2 USB ports (1 x type A, 1 x type B)

System General

System Type

Discrete, automated, random access, patient prioritized, clinical chemistry analyzer, 1,2, 3 reagent system

Throughput

Upto 1040 tests/hr (800 tests/hr) photometric and 240 tests/hr with ISE (4 Channel)*

Analytical Methods

1-Point, 2-Point, Rate-A, Rate-B, Direct Potentiometry

Barcode Reader

For reagents and samples

Reaction Tray

147 hard glass cuvettes

Reaction Mixing

Stirrer with variable speed

Reading Volume

Reaction volume 150 ul

On-board Laundry

7 stage cleaning, 2 stage drying

Photometer

Multi-wavelength diffraction grating with 15 wavelengths (340, 376, 405, 450, 480, 505, 528, 546, 570, 600, 628, 660, 700, 750 and 800 nm)

Calibration

K-Factor, Linear (1, 2 point & multipoint), 4P and SP Logit-log, cubic spline, exponential, polynomial. On-board serial dilution for calibrator

OD Range

0.0 - 3.0

Light Source

Tungsten halogen lamp

Detector

Silicon photo-diode

Water Consumption

<25 litres /hr

Programmable Parameters:

Default system pack parameters + upto 99 user defined parameters, Unlimited profiles and unlimited calculation items

Quality Control

QC plot data with QC rules. Provision for lab mean. Twin plot

Power Requirement

AC220V± 10%,50 Hz or AC 110 V± 10%, 60 Hz

Power Consumption

2000VA.

Dimensions (mm)

Approx . 1350 (L) x 1000 (D) x 1250 (H)

Weight

Approx . 275 kgs.

Sample

Serum, Urine, Plasma, CSF, whole blood, other.

Standard / STAT Carousal

44 positions

Sample Rack

Upto 150 samples can be placed simultaneously (excluding standards, calibrators & controls)

Sample Pipetting

2 -60 µl (adjustable in 0.1 µIstep) for Biochemistry, 70 µl (fixed) for ISE Capacitance probe with level sensing, vertical obstruction detection, Clot detection and serum indices

Auto Rerun

Repeat with same, increased or decreased volume (upto 1:150)

Sample Tubes/ Cups

Primary tubes of 5 ml, 7 ml, 10 ml and sample cups

Reagent Tray

86 reagent positions with on-board refrigeration

Reagent Pipetting

Two separate probes for Rl, R2 & R3 Rl:60-300 µl (adjustable in 0.5 µl)

R2

0, or 10- 200 µl (adjustable in 0.5 µl)

R3

0, or 10- 200 µl (adjustable in 0.5 µl) Capacitance probe with liquid level sensing & vertical obstruction detection

Analyzer - PC

RS - 232 C Serial Port PC - Host

Computer

Bidirectional TCP/IP & RS-232

PC - Printer

USB

Operating system

Windows-based

Database

Unlimited results

How does a coagulation analyzer work?
Coagulation analyzers work by mixing a blood sample with specific reagents to initiate clot formation. The analyzer then measures the time it takes for the blood to clot, providing valuable information about the blood's coagulation status.
The ECL 105 Coagulation analyser is based on the Optical Scattered light principle.
PT (Prothrombin Time) measures the extrinsic pathway of coagulation, while aPTT (Activated Partial Thromboplastin Time) measures the intrinsic pathway. Both tests assess different aspects of the clotting process.
The time taken to get results varies depending on the specific test being performed and the type of analyzer. Generally, results are available within a few minutes to an hour.
Yes, most modern coagulation analyzers can test multiple parameters simultaneously, including prothrombin time (PT), activated partial thromboplastin time (aPTT), and fibrinogen levels.
Yes, many coagulation analyzers can be integrated with laboratory information systems for seamless data transfer and improved workflow management.
Abnormal coagulation results can indicate various conditions, such as bleeding disorders, liver disease, vitamin K deficiency, or the presence of anticoagulant medications.

Reagent Information

Erba Control P
Prepared from Pooled plasma and used as Pathological Control..
Erba Control N Plus
Prepared from Pooled plasma and used as Normal Control..
Erba Control P Plus
Prepared from Pooled plasma and used as Pathological Control..
Erba DDimer Control N + P
Prepared from Pooled plasma and used as Normal / Pathological Control..
Erba Standard Plasma
Used as Calibrator..
Erba DDimer Calibrator
Used as Calibrator..
Erba Owren Veronal Buffer
Buffer is used in dilution preparation..
Erba Single Reaction Cuvettes SRC10
Used as consumable in testing..
Erba Calcium Chloride
Used in APTT assay..
Erba Thrombin Reagent
It is used in the Quantitative determination of Fibrinogen in Patient Plasma samples..
Erba Control N
Prepared from Pooled plasma and used as Normal Control..
Erba D Dimer R – Quantitative D Dimer (DDR)
It is used in the Quantitative determination D-dimer in Patient Plasma samples..
Erba Protime LS
It is used in the determination of Prothrombin Time (PT)..
Erba Actime
It is used in the determination of APTT..
No data found
No data found

Hear it From Our Happy Customers

Expert Speak

Resources

Blog

26 Jun 2024

A blood test today holds the key to every treatment outcome. In the wake of...

Blog

26 Jun 2024

The automation of ELISA systems, in the recent past, has contributed to improving the turnaround...

Blog

26 Jun 2024

Diabetes affects approximately 1 in 10 adults globally, with over 90% of cases being attributed...

Whitepaper

19 Apr 2024

Abstract Introduction: Fresh Frozen Plasma (FFP) is a blood component separated from whole blood and...

Whitepaper

25 Jun 2024

Click to know more: http://www.mdpub.net/?mno=132810 Introduction: Dengue is a highly prevalent mosquito-borne disease caused by...

Whitepaper

25 Jun 2024

Introduction: Electrolytes in the body are electrically charged minerals—such as sodium, potassium, calcium, phosphorous, and...

News

19 Apr 2024

Add Your Heading Text Here ErbaLisa HCV Gen 4 Ag+Ab | India’s first and only...

News

15 May 2024

Timely and targeted diagnosis is key for the development of disease prevention programs and optimal...

News

15 May 2024

Dr. Ravi Kannan of Cachar Cancer Hospital Awarded Padma Shri Dr Ravi Kannan, a renowned...

People Also Look For

WhatsApp

Enquiry form

Product Name

ECL 105

Product Category

Enquiry form