ECL 412
Four Channel Semi Automated Coagulation Analyzer
![](https://erba.velocitabrandconsultants.com/wp-content/uploads/2024/05/1ECL-412.jpg)
![](https://erba.velocitabrandconsultants.com/wp-content/uploads/2024/05/2ECL-412.jpg)
![](https://erba.velocitabrandconsultants.com/wp-content/uploads/2024/05/3ECL-412.jpg)
ECL 412
Four Channel Semi Automated Coagulation Analyzer
Meet the ECL 412
It’s an advanced analyzer for Complete Hemostasis. This four channel coagulation analyzer redefines the benefits in its class. Erba ECL 412, can perform PT, APTT, Fibrinogen, Thrombin Time , All Factors, Lupus , Protein S, Protein C , Antithrombin III and DDimer.
Product Specifications
![f1 f1](https://erba.velocitabrandconsultants.com/wp-content/uploads/elementor/thumbs/f1-10-qoh1pxr22476mj9ell0k5ce9jnh41aah9vdtbpdojk.png)
Detection
Optical Detection at 640 nm
Your Benefit:
Helps to overcome HIL interference
![f2 f2](https://erba.velocitabrandconsultants.com/wp-content/uploads/elementor/thumbs/f2-10-qoh1pxr22476mj9ell0k5ce9jnh41aah9vdtbpdojk.png)
Testing Assay
Clotting, Chromogenic and Immunoturbidometry assays for Routine & Special parameters
Your Benefit:
Multi-Parameter testing helps Clinicians to diagnose better
![f3 f3](https://erba.velocitabrandconsultants.com/wp-content/uploads/elementor/thumbs/f3-10-qoh1pyow8y8gy581g3f6pu5q51ch8ze7m01aszcadc.png)
Display
Large graphic, alpha-numeric, color touch screen display
Your Benefit:
Ensures ease of operation
![f4 f4](https://erba.velocitabrandconsultants.com/wp-content/uploads/elementor/thumbs/f4-10-qoh1pyow8y8gy581g3f6pu5q51ch8ze7m01aszcadc.png)
Results
Automated results calculation
Your Benefit:
Supports in ease of clinical interpretations
![f5 f5](https://erba.velocitabrandconsultants.com/wp-content/uploads/elementor/thumbs/f5-10-qoh1pyow8y8gy581g3f6pu5q51ch8ze7m01aszcadc.png)
Quanlity Control
Quality Control with L-J chart
Your Benefit:
Ensures test results are as per guidelines
![f6 f6](https://erba.velocitabrandconsultants.com/wp-content/uploads/elementor/thumbs/f6-7-qoh1pzmqfs9r9r6oalttabx6qf7ugohxy4osa9aw74.png)
Compatibility
LIS Compatibility
Your Benefit:
Ensures the elimination of transcription errors
Clotting Tests such as PT, aPTT, Fibrinogen, Thrombin time, Factors, Lupus anticoagulant, Protein S can be performed using Light scatter principle
Protein C, Antithrombin III can be done by Chromogenic Principle
Tests like D Dimer can be performed using Immuno-turbidimetry principle
Technical Specification
General Specifications
- 4 channel semi-automated hemostasis instrument
- It can perform 4 simultaneous tests of the same parameter
- Sample id can be 14 digits alphanumeric, with progressive id or custom id options
- It is also possible to have a second row of assay preparation/incubation during the analysis of the current line, using preparation line option
- It can run assays in single or duplicate (programmable per assay)
- Optically detects and automatically moves to the next assay steps and auto starts the measurements
Tests principles
- Clotting (scattered light at 640nm)
- Chromogenic (colorimetry at 405nm)
- Immuno-turbidimetric (turbidimetry at 800nm)
Dimensions / Weight
- Dimension : 300 x 290 x 90 mm
- Weight : 3 kgs
Environmental requirements
- Operating Temperature : 17-32°C
- Humidity: Max. 80% Relative Humidity, non-condensing
Power
- Power Supply: 100-240 VAC and 50/60 Hz
- Power Consumption: 45 Watts
- In-Rush Power: 150VA or less
Calibrations
- Up to 6 calibration levels per assay
- Storage of the active calibration curve
Quality Controls
- Up to 12 different control names total can be assigned to any given assay
- Automatic Levey-Jennings plotting
- Automatic statistics calculation
- Storage of Quality Control results
Stored results
- Independent storage allocation in the instrument memory for Quality Control (QC) and patient determinations
- Up to 600 results for QC determinations (run in duplicate)
- Up to 900 results for patients (run in duplicate)
- New results automatically replace the oldest results of the appropriate category past the maximum storage allowance
- Reaction curves are exclusively stored on the external USB pendrive.
- Regular backup and file purging is recommended from the USB pendrive to insure rapid operations. (We recommend at least a monthly purge from a computer to back up and remove CH files)
- USB pendrive , FAT32 formatted