ECL 760

Seven Channel Fully Automated Random Access Analyzer for Complete Hemostasis
Meet the ECL 760
It’s an advanced, fully automated random access analyzer for Complete Hemostasis. This seven channel coagulation analyzer redefines the benefits in its class. This system is ideal for mid-high range coagulation workload, especially for routine PT, aPTT and some rare parameters.

Product Specifications

1
Detection
Optical Detection at 640 nm
Your Benefit:

Helps to overcome HIL interference

2
Testing Assay
Clotting, Chromogenic and Immunoturbidometry assays for Routine & Special parameters
Your Benefit:

Multi-Parameter testing helps Clinicians to diagnose better

3
Display
Large graphic, alpha-numeric, color touch screen display
Your Benefit:

Ensures ease of operation

4
Result
Automated results calculation
Your Benefit:

Supports in ease of clinical interpretations

5
Result Calculation
Quality Control with L-J chart
Your Benefit:

Ensures test results are as per guidelines

6
Interface
Bi-Directional LIS interface
Your Benefit:

It streamline operations, reduce errors and improves accuracy

7
Flexibility
Your Benefit:

It has Large onboard Capacity, Continuous loading & STAT management

Clotting Tests such as PT, aPTT, Fibrinogen, Thrombin time, Factors, Lupus anticoagulant, Protein S can be performed using Light scatter principle
Protein C, Antithrombin III can be done by Chromogenic Principle
Tests like D Dimer can be performed using Immuno-turbidimetry principle
Technical Specification

Throughput

Fully Automated Random Access Coagulation Analyzer

Tests principles

  • PT : 45Tests/Hour
  • APTT 30 Tests/Hour
  • PT,APTT :35 Tests/Hour

Principle of Detection

  • Clotting: Scattered Light Detection Method
  • Chromogenic : Colorimetric Method
  • Immunoturbidimetry : Latex Enhanced Turbidimetric Method

Detection Channels

Seven numbers

Detection optics

LEDBasedwith640 nm, 405 nm, and575 nm

Incubation Channels

Eight numbers

Clot detection

Curve monitoring

Sample ID

20 Characters custom, automatic generation possible

Units of measurement

seconds ,dOD, % Ratio, INR, Dfbg

Sample Types

STAT, patientsample, control

Minimal Sample Volumes

PT,APTT, TT:50 ul; Fbg, ATIl: 10 pl; Factor Assays: 5 u Erba D-Dimer R: 15 pl

No. Of Sample Racks

Three

Total Number of Samples

27 numbers, continuous loading

Sample Barcode Reader

Yes

Tests Per Group

10

Reagents on-board

20 reagents cooled at 13-15°C.3reagent locations for Clean, Diluentand Buffe

Dispensing

Pre-heating probe, with level sensing and vertical obstruction detection

Calibration Mode

Manual and Automatic

Calibration

6 Calibration points

Reagent Management

Lot Number, Expiry, Reagen tName and Type, Volume monitoring

Analysis modes

Re-dilution, Re-testing, Repeat analysis

Incubation

  • Volume monitoring Detector : 37°C+1°C
  • Sample Incubator Section : 37*C+ 1°C
  • IReagent Pipette :37°C+1°C

Quality Control algorithm

L-J and Multi rules, 12 levels

Display

Graphical touch screen display

Printer

Built-in printer

Operating System

Windows XP

Factor Assay

Generation of Standard curve

Mains input

AC 100V/220V, 50Hzor60Hz

Input power

400VA

Operational environment

10°C~30°C, relative humidity 70<%

Storage environment

-20°C~55°C, relative humidity s 85<%

Dimension LxWx H

660x 580 x510

Weight

53 kg

What is the principle of ECL 760 Coagulation Analyzer?
The ECL 760 Coagulation analyser is based on the Optical Scattered light principle.
Yes, most modern coagulation analyzers can test multiple parameters simultaneously, including prothrombin time (PT), activated partial thromboplastin time (aPTT), and fibrinogen levels.
Yes, many coagulation analyzers can be integrated with laboratory information systems for seamless data transfer and improved workflow management.
Yes, coagulation analyzers are commonly used to monitor patients on oral anticoagulant therapy, helping healthcare providers adjust medication dosages to maintain optimal clotting levels.
Coagulation analyzers should be calibrated according to the manufacturer's guidelines, typically every 1 to 6 months, depending on usage and the specific model.
Yes, coagulation analyzers can be used for pediatric patients. There are specific pediatric reference ranges, and the analyzer can be adjusted accordingly.
Yes, reagents often have specific storage temperature and handling instructions provided by the manufacturer. It's crucial to follow these guidelines to maintain their effectiveness.

Reagent Information

Erba Control P
Prepared from Pooled plasma and used as Pathological Control..
Erba Control N Plus
Prepared from Pooled plasma and used as Normal Control..
Erba Control P Plus
Prepared from Pooled plasma and used as Pathological Control..
Erba DDimer Control N + P
Prepared from Pooled plasma and used as Normal / Pathological Control..
Erba Standard Plasma
Used as Calibrator..
Erba DDimer Calibrator
Used as Calibrator..
Erba Owren Veronal Buffer
Buffer is used in dilution preparation..
Erba Single Reaction Cuvettes SRC10
Used as consumable in testing..
Erba Clean l
It is used to decontiminate the probe..
Erba D Dimer R – Quantitative D Dimer (DDR)
It is used in the Quantitative determination D-dimer in Patient Plasma samples..
Erba Protime LS
It is used in the determination of Prothrombin Time (PT)..
Erba Actime
It is used in the determination of APTT..
Erba Calcium Chloride
Used in APTT assay..
Erba Thrombin Reagent
It is used in the Quantitative determination of Fibrinogen in Patient Plasma samples..
Erba Control N
Prepared from Pooled plasma and used as Normal Control..
No data found
No data found

Hear it From Our Happy Customers

Expert Speak

Resources

Blog

26 Jun 2024

A blood test today holds the key to every treatment outcome. In the wake of...

Blog

26 Jun 2024

The automation of ELISA systems, in the recent past, has contributed to improving the turnaround...

Blog

26 Jun 2024

Diabetes affects approximately 1 in 10 adults globally, with over 90% of cases being attributed...

Whitepaper

19 Apr 2024

Abstract Introduction: Fresh Frozen Plasma (FFP) is a blood component separated from whole blood and...

Whitepaper

25 Jun 2024

Click to know more: http://www.mdpub.net/?mno=132810 Introduction: Dengue is a highly prevalent mosquito-borne disease caused by...

Whitepaper

25 Jun 2024

Introduction: Electrolytes in the body are electrically charged minerals—such as sodium, potassium, calcium, phosphorous, and...

News

19 Apr 2024

Add Your Heading Text Here ErbaLisa HCV Gen 4 Ag+Ab | India’s first and only...

News

15 May 2024

Timely and targeted diagnosis is key for the development of disease prevention programs and optimal...

News

15 May 2024

Dr. Ravi Kannan of Cachar Cancer Hospital Awarded Padma Shri Dr Ravi Kannan, a renowned...

People Also Look For

WhatsApp

Enquiry form

Product Name

ECL 760

Product Category

Enquiry form