Lisa wash
Automated microplate washer.
![](https://erba.velocitabrandconsultants.com/wp-content/uploads/2024/05/1Lisa-Wash.jpg)
![](https://erba.velocitabrandconsultants.com/wp-content/uploads/2024/05/2Lisa-Wash.jpg)
Lisa wash
Automated microplate washer.
Meet the Lisa wash
Product Specifications
![f1 f1](https://erba.velocitabrandconsultants.com/wp-content/uploads/elementor/thumbs/f1-12-qoh39beqpq0cngti80s9jvaxhwimjb55vz2o7l9ny8.png)
Intended Use
Automated ELISA Microplate Washer
Your Benefit:
Washer with complete flexibility to program number of wash, dispensing volume, soak time
![f2 f2](https://erba.velocitabrandconsultants.com/wp-content/uploads/elementor/thumbs/f2-12-qoh39beqpq0cngti80s9jvaxhwimjb55vz2o7l9ny8.png)
Programs
50 user defined protocol
Your Benefit:
Program different parameters of different brands without deleting the previous one
![f3 f3](https://erba.velocitabrandconsultants.com/wp-content/uploads/elementor/thumbs/f3-12-qoh39beqpq0cngti80s9jvaxhwimjb55vz2o7l9ny8.png)
Manifold
8 and 12 Channel Manifold options
Your Benefit:
Get better speed with 12 channel manifold when the workload is high
![f4 f4](https://erba.velocitabrandconsultants.com/wp-content/uploads/elementor/thumbs/f4-12-qoh39cckwk1mz2s52j6w4d2e3adzr08w83q5ov89s0.png)
Accuracy
2 Point aspiration
Your Benefit:
Ensures minimal residual volume, eliminates background, and delivers reliable and reproducible results
![f5 f5](https://erba.velocitabrandconsultants.com/wp-content/uploads/elementor/thumbs/f5-12-qoh39cckwk1mz2s52j6w4d2e3adzr08w83q5ov89s0.png)
Security
Auto vacuum pressure
Your Benefit:
Avoids clogs or blockages in needles
![f6 f6](https://erba.velocitabrandconsultants.com/wp-content/uploads/elementor/thumbs/f6-9-qoh39daf3e2xaoqrx1lioutuoo9cypcmk8dn656vls.png)
LLS
Liquid Level sensor in waste bottle
Your Benefit:
Gives alarm when the waste is full to avoid overflow
![f7 f7](https://erba.velocitabrandconsultants.com/wp-content/uploads/elementor/thumbs/f7-6-qoh39daf3e2xaoqrx1lioutuoo9cypcmk8dn656vls.png)
Protection
Standard aerosol cover
Your Benefit:
Protect the content of microplate from contaminantsss
ELISA microplates washing
Technical Specification
Touch Screen
8 and 12 wash head manifold compatible
Wash mode - Row and Plate
Plate type - 96 well plate (V, U, Flat)
Dispensing volum - 50 - 450 ul in 5ul increments
2 different washing solutions of 2 liters bottle capacity
Up to 64 wash protocols
System General
System Type
Discrete, automated, random access, patient prioritized, clinical chemistry analyzer, 1,2, 3 reagent system
Throughput
Upto 1040 tests/hr (800 tests/hr) photometric and 240 tests/hr with ISE (4 Channel)*
Analytical Methods
1-Point, 2-Point, Rate-A, Rate-B, Direct Potentiometry
Barcode Reader
For reagents and samples
Reaction Tray
147 hard glass cuvettes
Reaction Mixing
Stirrer with variable speed
Reading Volume
Reaction volume 150 ul
On-board Laundry
7 stage cleaning, 2 stage drying
Photometer
Multi-wavelength diffraction grating with 15 wavelengths (340, 376, 405, 450, 480, 505, 528, 546, 570, 600, 628, 660, 700, 750 and 800 nm)
Calibration
K-Factor, Linear (1, 2 point & multipoint), 4P and SP Logit-log, cubic spline, exponential, polynomial. On-board serial dilution for calibrator
OD Range
0.0 - 3.0
Light Source
Tungsten halogen lamp
Detector
Silicon photo-diode
Water Consumption
<25 litres /hr
Programmable Parameters:
Default system pack parameters + upto 99 user defined parameters, Unlimited profiles and unlimited calculation items
Quality Control
QC plot data with QC rules. Provision for lab mean. Twin plot
Power Requirement
AC220V± 10%,50 Hz or AC 110 V± 10%, 60 Hz
Power Consumption
2000VA.
Dimensions (mm)
Approx . 1350 (L) x 1000 (D) x 1250 (H)
Weight
Approx . 275 kgs.
Sample Handling
Sample
Serum, Urine, Plasma, CSF, whole blood, other.
Standard / STAT Carousal
44 positions
Sample Rack
Upto 150 samples can be placed simultaneously (excluding standards, calibrators & controls)
Sample Pipetting
2 -60 µl (adjustable in 0.1 µIstep) for Biochemistry, 70 µl (fixed) for ISE Capacitance probe with level sensing, vertical obstruction detection, Clot detection and serum indices
Auto Rerun
Repeat with same, increased or decreased volume (upto 1:150)
Sample Tubes/ Cups
Primary tubes of 5 ml, 7 ml, 10 ml and sample cups
Reagent Handling
Reagent Tray
86 reagent positions with on-board refrigeration
Reagent Pipetting
Two separate probes for Rl, R2 & R3 Rl:60-300 µl (adjustable in 0.5 µl)
R2
0, or 10- 200 µl (adjustable in 0.5 µl)
R3
0, or 10- 200 µl (adjustable in 0.5 µl) Capacitance probe with liquid level sensing & vertical obstruction detection
System Interface
Analyzer - PC
RS - 232 C Serial Port PC - Host
Computer
Bidirectional TCP/IP & RS-232
PC - Printer
USB
Operating system
Windows-based
Database
Unlimited results